Maintenance
312185S 11
Maintenance
Daily Shutdown
When you are through using the MD2 valve, the outlet to
the mixer should be cleaned and protected from drying
or crystallization.
1. Remove and properly dispose of the static mixer.
2. Dispense a shot of material into a waste container
to clear any crossover in the nosepiece.
3. Wipe the nose with a clean rag being careful not to
let the materials contact each other.
4. Install the PTFE night cap (1:1 valves - 15K652,
10:1 valves - 15K628) and retaining nut (15K688).
Preventive Maintenance
There is a grease filled secondary seal/bearing area on
each valve shaft. Every 10,000 cycles, or twice each
month, new grease should be flushed across this area.
To grease the valve:
1. Remove the zerk grease fitting from each side of the
front or back of the valve.
2. Pump grease (115982) with grease gun (117792)
across the valve until clean grease comes out of the
other side.
3. Reinstall the zerk grease fitting.